In a Nutshell
Technical Details
|
Throughput |
kg/h |
up to 80 kg/h Cl2 |
|
|---|---|---|---|
|
Operating pressure |
-1 – 0 bar |
||
|
Contact gauge |
Ø63 mm, class 2.5 |
||
|
Setting range of the switching |
-0,9 – -0,1 bar |
||
|
Changeover time |
approx. 22 s |
||
|
Material in contact with the media |
PVC / FPM / Silver / coated brass |
||
|
Further materials |
Coated steel, PP, ABS |
||
|
Voltage supply |
115 – 230 V AC |
||
|
Protection class |
IP65 |
||
|
Load capacity of the relay |
max. 3 A / 250 V AC |
||
|
Weight |
approx. 7 kg |
||
|
Ambient temperature |
0 – 55 °C, |
Subject to technical changes